• SLB-125-200 SLB-Series DC Load Tester

SLB-125-200 SLB-Series DC Load Tester

(0)No Reviews yet

Overview

The Eagle Eye Power Solutions SLB-125-200 SLB-Series DC Load Tester is engineered for reliable capacity and performance testing of 125V battery systems with discharge capability up to 200 amps. Designed for utility substations, telecom facilities, data centers, and industrial DC applications, this model provides programmable constant-current discharge testing — the only verifiable method to confirm true battery capacity.

With built-in safety features, auto-shutdown protections, and optional per-cell monitoring via DAC packages, the SLB-125-200 increases both technician safety and system reliability. The unit supports wireless remote monitoring and integrates with DataView software for live test viewing, data recording, and Excel-ready report exporting.

For expanded testing capability, the SLB-125-200 can be paralleled with another SLB-Series unit to increase discharge current capacity. It can also operate in assistant discharge mode alongside existing non-SLB load banks, allowing users to modernize testing systems without fully replacing legacy equipment.

Features

  • 125V System Testing: Designed specifically for 125V battery strings and DC systems.
  • Up to 200A Programmable Discharge: Constant-current load testing for accurate capacity verification.
  • Automatic Discharge Shutdown: Configurable protection based on time, total string voltage, capacity, or individual cell voltage.
  • Wireless Remote Monitoring (466 MHz): Safely monitor live discharge tests remotely.
  • DataView Software Included: Live monitoring, data logging, and exportable reports to Microsoft Excel.
  • Parallel Capability: Connect additional SLB-Series units to increase discharge current capacity.
  • Assistant Discharge Mode: Compatible with existing non-SLB load banks to expand testing capability.
  • Built-In Circuit Breakers: Provides overload protection and emergency shutdown capability.
  • Optional DAC Package: Real-time per-cell voltage monitoring for 1.2V, 2V, 6V, and 12V cells (custom configurations available).
  • Backlit LCD Display: Clear on-site visibility of test parameters and system status.

Specifications

Nominal System Voltage: 125 VDC
Discharge Current Range: 12 – 200A (Single Unit) / Up to 1200A (Parallel with Additional SLB Units)
Discharge Voltage Range: 10 – 576V (Max System Capable)
Voltage Steps: 12V, 24V, 36V, 48V, 80V, 125V, 240V, 380V, 480V
Accuracy: Discharge Current: ±1% / Voltage: 0.5% – 0.8%
Resolution: Discharge Current: 0.1A or 0.5% / Voltage: 0.001V
Sampling Interval: 5 Seconds – 1 Minute
Data Transfer: USB, Wireless (466 MHz)
Display: Backlit LCD
Cell Voltage Monitoring (Optional DAC): Standard: 1.2V, 2V, 6V, 12V / Optional: 3.6V, 4V, Custom Configurations Available
Operating Environment: 0 – 40 °C (32 – 104 °F)
Power Requirements: 110/220 VAC 50/60 Hz or DC (From Connected Battery)
Dimensions: Varies by Enclosure Size (Small through XX-Large)
Weight: Varies by Enclosure Size (24 – 122 lbs)

Resources & Support

FAQs

Why is discharge testing necessary for battery systems?

Discharge testing is the only verifiable method to confirm true battery capacity. It ensures the battery system can support required loads during an outage and identifies weak cells before failure occurs.

Is the SLB-125-200 suitable for NERC compliance testing?

Yes. The SLB-125-200 provides programmable constant-current discharge testing and exportable reporting through DataView software, supporting documentation requirements for NERC-related maintenance programs.

Can I increase discharge current beyond 200 amps?

Yes. The SLB-125-200 can be paralleled with another SLB-Series unit to increase total discharge current capacity while maintaining programmable control and monitoring.

Does the SLB-125-200 support individual cell monitoring?

Yes. With the optional DAC package, the SLB-125-200 can provide real-time voltage monitoring for individual cells including 1.2V, 2V, 6V, and 12V configurations. Custom DAC options are also available.

Can this unit be used with existing load banks?

Yes. The Assistant Discharge feature allows the SLB-125-200 to operate alongside existing non-SLB load banks, increasing current capacity and adding monitoring capability without replacing legacy equipment.

What battery systems is the SLB-125-200 designed for?

The SLB-125-200 is designed for 125V DC battery systems commonly found in utility substations, telecom facilities, data centers, and industrial power applications.